TOPIC: Double tapped 15 and 20 amp breakers-

Re: Double tapped 15 and 20 amp breakers- 12 years 5 months ago #49104

I think there is a difference in these types of situations.  When I call out a double tap, it is because there are two conductors installed where only a single conductor is allowed.  I would not consider a breaker designed for two conductors to be double tapped as it is meeting the design specs.

Please Log in to join the conversation.

There is nothing sweeter than the smell of fresh cut grass on a baseball infield, the click of a wooden bat and the taste of a hot dog at a warm sunny daytime double-header.

Re: Double tapped 15 and 20 amp breakers- 12 years 5 months ago #49115

Mike K, it's a double tap. Call it out and move on. No over analysis needed.

Please Log in to join the conversation.

Title: San Antonio Home Inspections
Site: www.jwkhomeinspections.com
Body: JWK Inspections, San Antonio Home Inspector, Performing Home Inspections in San Antonio & all surrounding areas.
Keywords: San Antonio Home Inspections, New Home Construction Inspections, New Braunfels, Schertz, Home...

Re: Double tapped 15 and 20 amp breakers- 12 years 5 months ago #49190

What types of breakers will allow two wires or is it easier to ask which ones don't? 

Please Log in to join the conversation.

Jesus is coming again!!

Re: Double tapped 15 and 20 amp breakers- 12 years 5 months ago #49192

As far as I know, Square D has those type, but not all Sq D are designed for it. The square washer under the screw is designed for two wire connections. What makes double-tapping a hazard is that the screw and washer can't make good contact on both wires, whereas the Square D type is made for it. There is still the issue of nuisance tripping due to excessive amperage, which I would mention in my report.

Please Log in to join the conversation.

Always tell the truth, do what you promise, and do it righter than right..always
Title: Inspection Connection
URL: www.charleston-home-inspector.com
Body: Performing Home Inspections in all of WV: Charleston, Huntington, Teays, Hurricane, and surrounding areas
Keywords: Charleston Home Inspector, St...

Re: Double tapped 15 and 20 amp breakers- 12 years 5 months ago #49193

Michael,
I've seen the square D breakers with the washer I think you are referring to.  Those are the type that have a notch on each side?
Have a good night    

Please Log in to join the conversation.

Jesus is coming again!!

Re: Double tapped 15 and 20 amp breakers- 12 years 5 months ago #49194

yes sir, that be the ones. see ya next time, Mike!

Please Log in to join the conversation.

Always tell the truth, do what you promise, and do it righter than right..always
Title: Inspection Connection
URL: www.charleston-home-inspector.com
Body: Performing Home Inspections in all of WV: Charleston, Huntington, Teays, Hurricane, and surrounding areas
Keywords: Charleston Home Inspector, St...
Time to create page: 0.179 seconds
© 2004-2024 Home Inspector Pro Inc. All Rights Reserved.