• 888-750-4777
  • This email address is being protected from spambots. You need JavaScript enabled to view it.
Welcome, Guest
Username: Password: Remember me

TOPIC: Roof Plumbing Vent to Short

Re: Roof Plumbing Vent to Short 15 years 6 months ago #3420

Now this is what I'm talking about :D Great discussion.

Please Log in to join the conversation.

Dominic Maricic
Home Inspector Pro Home Inspection Software - CEO

Re: Roof Plumbing Vent to Short 15 years 6 months ago #3446

And with very little cussing..SNAFU!  LOL.

Greg

Please Log in to join the conversation.

Greg Scheer
www.GCSHomeInspections.com
Body and Meta Description: Home Inspection and Thermal Imaging in Scranton, Montrose, Honesdale, Wilkes-Barre, and northeastern Pennsylvania. Call 570-504-8393
Meta: Home, Inspector, Montrose, Scranton, Thermal, Inspections
URL: Montrose-Home-Inspector.html...

Re: Roof Plumbing Vent to Short 15 years 6 months ago #3449

Systems Normal All Frigged Up??

Please Log in to join the conversation.

Jay Markanich Real Estate Inspections, LLC
Based in Bristow, serving all of Northern Virginia
www.jaymarinspect.com
Northern Virginia Home Inspector
Festina Lente - Make Haste Slowly

Re: Roof Plumbing Vent to Short 15 years 6 months ago #3452

LOL

Please Log in to join the conversation.

Dominic Maricic
Home Inspector Pro Home Inspection Software - CEO

Re: Roof Plumbing Vent to Short 15 years 6 months ago #3469

Also Gas pipe needs to be painted Grey for identification, and the joints do not have dope/yellow tape but rather white tape which is not exterior grade, it is for interior water connections. Exterior should be dope( mastic) and have at least 1/16 inch roll at the end of the pipe fitting to ensure the dope has sealed the joint.
The strapping connecting the Vent piping needs further investgation, if in fact they did the main floor hook up, the may have used the vent stack as grounding, seen it before and now its grounded to the gas pipe by way of banding.

Please Log in to join the conversation.

Certified level I Thermographer (FLIR)
Certified Home Inspector #07040201
Certified Mold Inspector #7310 (ESA)
Certified Commercial Inspector
IAQ, Radon, Asbestos, lead

Re: Roof Plumbing Vent to Short 15 years 6 months ago #3472

That's a good point.  Grounding, something we cant see, and a big no no.

Please Log in to join the conversation.

HLC Home Inspections LLC
www.OklahomaHomeInspector.biz
We are a licensed inspector for the state of Oklahoma.?  Our focus is Oklahoma City, Moore, Mustang, Yukon, Tuttle, and many other areas surrounding OKC.
HLC-Home-Inspections-Oklahoma-City

HLC Home Inspections LLC...
Time to create page: 0.196 seconds
© 2004-2024 Home Inspector Pro Inc. All Rights Reserved.