• 888-750-4777
  • This email address is being protected from spambots. You need JavaScript enabled to view it.
Welcome, Guest
Username: Password: Remember me
  • Page:
  • 1
  • 2

TOPIC: Any Ideas?

Re: Any Ideas? 12 years 10 months ago #41747

Hey Jeffrey--

The incoming lines as well as all of the interior lines were copper.  From what I remember he continually was cleaning the screens as he reported "they got clogged again as soon as he cleaned them"--I don't know if the problem has gone away over time but I intend to sak him--More later

Please Log in to join the conversation.

Re: Any Ideas? 12 years 10 months ago #41748

Bob, a standard procedure when de-winterizing the water system, is to remove all screens and flush the system completely. I'm guessing he did the de-winterizing himself, and wasn't aware of this step. It's not just about turning the water back on. Hopefully he doesn't have any concealed leaks. Also, recommend he have the WH drain spigot replaced, and flush out the tank. If the WH is electric, have the sacrificial anode checked/replaced, as well as the heating elements, at that time.

Please Log in to join the conversation.

Jeffrey R. Jonas
507.213.7468
This email address is being protected from spambots. You need JavaScript enabled to view it.

FB: www.facebook.com/MN.Home.Inspector

www.JRJConsultants.net
www.OwatonnaHomeInspector.com
www.MinnesotaCommercialBuildingInspections.com

URL: www.owatonnahomeinspector.com
Title: Critical Eye Property Inspections
Description: Providing...
  • Page:
  • 1
  • 2
Time to create page: 0.179 seconds
© 2004-2024 Home Inspector Pro Inc. All Rights Reserved.